Liquid Cold Plate Cooling for Server CPUs
Why Air Cooling Fails Modern Server Demands
The Limitations of Traditional Thermal Management
Air-cooled server CPUs face critical challenges as computational demands skyrocket:
▶️ 40-45% of data center energy consumed by cooling systems (Uptime Institute, 2023)
▶️ 65 dB+ noise levels from high-RPM fans impacting workplace environments
▶️ Thermal throttling reduces CPU performance by up to 30% at 85°C+
The Breaking Point: A 2023 hyperscale data center study revealed air-cooled racks hitting 15kW density limits, forcing costly infrastructure expansions.
Liquid Cold Plate Technology: Performance Breakthroughs
25x Thermal Conductivity Advantage Over Air Cooling
How Liquid Cold Plates Work
Parameter | Air Cooling | Liquid Cold Plate |
---|---|---|
Thermal Conductivity | 0.024 W/m·K | 0.6 W/m·K |
Heat Transfer Coefficient | 50-100 W/m²·K | 5,000-15,000 W/m²·K |
Temperature Differential | 20-30°C | 2-5°C |
Source: ASHRAE Thermal Guidelines Comparison
Key Performance Metrics
20°C Average Temperature Reduction: CPU junctions stabilize at 45-55°C vs. 65-75°C with air
70-80% Cooling Energy Savings: 0.8 PUE (Power Usage Effectiveness) achievable
25kW+ Rack Density Support: 3x higher than air-cooled limits
Real-World Applications: Enterprise to Hyperscale
Proven Liquid Cooling Case Studies
Case 1 – AI Training Cluster Optimization
Challenge: 10,000+ GPU cluster hitting 90°C thermal walls
Solution:
Direct-to-chip cold plates with 40L/min flow rate
50/50 water-glycol coolant at 35°C supply temperature
Results:
22% faster model training (eliminated throttling)
$2.1M annual energy savings (74% cooling cost reduction)
Case 2 – Edge Data Center Deployment
Constraints: 10ft² footprint with 30kW thermal load
Innovation:
Modular cold plates supporting hot-swappable server trays
Passive two-phase cooling loops requiring zero pumps
Metrics:
82 dB → 55 dB noise reduction
100% uptime in 40°C ambient environments
Case 3 – Sustainable Cloud Infrastructure
Goal: Achieve net-zero cooling for 20MW facility
Implementation:
Waste heat recycling via 60°C coolant output
AI-driven flow control saving 3.2M gallons/year
Certification: LEED Platinum with 0.78 annualized PUE
Future-Proof Advantages for Next-Gen CPUs
Ready for 500W+ Server Processors
3D Vapor Chamber Integration: Handles 1,000W/cm² heat fluxes (Intel Falcon Shores-ready)
Nanofluid Enhancements: Graphene-doped coolants boost conductivity 200%
Dynamic Thermal Control: Machine learning adjusts cooling per workload
The Green Computing Imperative
Liquid Cooling’s Sustainability Edge
45% lower carbon footprint vs. conventional cooling (The Green Grid, 2024)
95% water reuse in closed-loop systems
LEED/WEDG compliance simplified through precise thermal control
Case customer: A server customer in North China
▶Customer design requirements
Heat dissipation type: water cooling system;
Ambient temperature: T=40℃:
Liquid medium: 20% ethylene glycol solution;
Liquid inlet temperature: T.40℃℃;
Liquid flow rate: 0.8L/MIN;
Thermal power consumption: PcPu: 300W1350W1400W (2X), Size: 70*50mm;
Heat dissipation structure: brazing + shovel teeth, hose connects the entire water
cooling system;
▶Simulation Report




▶Product Presentation


Heat dissipation type: water cooling system;
Ambient temperature: T=40℃:
Liquid medium: 20% ethylene glycol solution;
Liquid inlet temperature: T.40℃℃;
Liquid inlet temperature: T.40℃℃;
Liquid flow rate: 0.8L/MIN;
Thermal power consumption: PcPu: 300W1350W1400W (2X), Size: 70*50mm;
Heat dissipation structure: brazing + shovel teeth, hose connects the entire water
cooling system;