WhatsApp

+61 449963668

info@tonecooling.com


Liquid Cold Plate Cooling for Server CPUs

Why Air Cooling Fails Modern Server Demands

The Limitations of Traditional Thermal Management
Air-cooled server CPUs face critical challenges as computational demands skyrocket:

  • ▶️ 40-45% of data center energy consumed by cooling systems (Uptime Institute, 2023)

  • ▶️ 65 dB+ noise levels from high-RPM fans impacting workplace environments

  • ▶️ Thermal throttling reduces CPU performance by up to 30% at 85°C+

The Breaking Point: A 2023 hyperscale data center study revealed air-cooled racks hitting 15kW density limits, forcing costly infrastructure expansions.


Liquid Cold Plate Technology: Performance Breakthroughs

25x Thermal Conductivity Advantage Over Air Cooling

How Liquid Cold Plates Work

ParameterAir CoolingLiquid Cold Plate
Thermal Conductivity0.024 W/m·K0.6 W/m·K
Heat Transfer Coefficient50-100 W/m²·K5,000-15,000 W/m²·K
Temperature Differential20-30°C2-5°C

Source: ASHRAE Thermal Guidelines Comparison

Key Performance Metrics

  • 20°C Average Temperature Reduction: CPU junctions stabilize at 45-55°C vs. 65-75°C with air

  • 70-80% Cooling Energy Savings: 0.8 PUE (Power Usage Effectiveness) achievable

  • 25kW+ Rack Density Support: 3x higher than air-cooled limits


Real-World Applications: Enterprise to Hyperscale

Proven Liquid Cooling Case Studies

Case 1 – AI Training Cluster Optimization

  • Challenge: 10,000+ GPU cluster hitting 90°C thermal walls

  • Solution:

    • Direct-to-chip cold plates with 40L/min flow rate

    • 50/50 water-glycol coolant at 35°C supply temperature

  • Results:

    • 22% faster model training (eliminated throttling)

    • $2.1M annual energy savings (74% cooling cost reduction)

Case 2 – Edge Data Center Deployment

  • Constraints: 10ft² footprint with 30kW thermal load

  • Innovation:

    • Modular cold plates supporting hot-swappable server trays

    • Passive two-phase cooling loops requiring zero pumps

  • Metrics:

    • 82 dB → 55 dB noise reduction

    • 100% uptime in 40°C ambient environments

Case 3 – Sustainable Cloud Infrastructure

  • Goal: Achieve net-zero cooling for 20MW facility

  • Implementation:

    • Waste heat recycling via 60°C coolant output

    • AI-driven flow control saving 3.2M gallons/year

  • Certification: LEED Platinum with 0.78 annualized PUE


Future-Proof Advantages for Next-Gen CPUs

Ready for 500W+ Server Processors

  • 3D Vapor Chamber Integration: Handles 1,000W/cm² heat fluxes (Intel Falcon Shores-ready)

  • Nanofluid Enhancements: Graphene-doped coolants boost conductivity 200%

  • Dynamic Thermal Control: Machine learning adjusts cooling per workload


The Green Computing Imperative

Liquid Cooling’s Sustainability Edge

  • 45% lower carbon footprint vs. conventional cooling (The Green Grid, 2024)

  • 95% water reuse in closed-loop systems

  • LEED/WEDG compliance simplified through precise thermal control

Case customer: A server customer in North China

▶Customer design requirements

Heat dissipation type: water cooling system;

Ambient temperature: T=40℃:

Liquid medium: 20% ethylene glycol solution;

Liquid inlet temperature: T.40℃℃;

Liquid flow rate: 0.8L/MIN;

Thermal power consumption: PcPu: 300W1350W1400W (2X), Size: 70*50mm;

Heat dissipation structure: brazing + shovel teeth, hose connects the entire water

cooling system;

▶Simulation Report
Eagle stream CPU
CPU liquid cold plate
CPU liquid cooling plate
CPU liquid cooling plate
▶Product Presentation
Eagle streamLiquid Cooling Plate
CPU liquid cold plateS

Heat dissipation type: water cooling system;

Ambient temperature: T=40℃:

Liquid medium: 20% ethylene glycol solution;

Liquid inlet temperature: T.40℃℃;

Liquid inlet temperature: T.40℃℃;

Liquid flow rate: 0.8L/MIN;

Thermal power consumption: PcPu: 300W1350W1400W (2X), Size: 70*50mm;

Heat dissipation structure: brazing + shovel teeth, hose connects the entire water

cooling system;

Scroll to Top

Get A Free Quote Now !

Contact Form Demo (#3)
If you have any questions, please do not hesitate to contatct with us.