Server Liquid Cooling Module Envelope Review for 1U, 2U and Custom Chassis
A server liquid cooling module RFQ should define the chassis envelope, processor or module platform, radiator space, pump requirement, hose routing, coolant, flow rate, pressure-drop limit and validation scope. For 1U, 2U and custom chassis, packaging constraints can be as important as the cold plate itself.
Send Server Module Envelope RequirementsView Server CPU Cold Plate Hub
Engineering Inputs to Confirm
| Chassis envelope | 1U, 2U, 4U or custom height, available radiator and tube routing space. |
|---|---|
| Cooling module | Cold plate, pump, radiator, fan, tube and fitting requirements. |
| Electrical/input limits | Pump voltage, fan airflow, noise target and control requirement if applicable. |
| Validation | Leak, pressure, vibration/serviceability and documentation needs. |
Related Product Paths

T4
Current listing data for engineering confirmation: 280-300 W -Intel Xeon -aluminium
View product pageRFQ Checklist
Upload a drawing, CAD file or thermal specification if available. If drawings are not ready, send the closest platform reference and the following inputs:
- Drawing or CAD file
- CPU/platform or module footprint
- Heat load and inlet temperature
- Coolant type and concentration
- Flow rate and pressure-drop target
- Port direction and hose routing
- Prototype quantity and annual demand
- Leak / pressure / cleanliness requirement
Common Review Risk
Related Engineering Resources
Parent page for platform cold plates, high-power CPU cold plates and server cooling modules.
General custom cold plate RFQ checklist for drawings, heat load, coolant, flow and pressure-drop inputs.
Related data center GPU and AI server cold plate review page.
Start a drawing-based RFQ with technical inputs and project notes.
External Engineering References
FAQ
What should be sent before quotation?
Send the drawing or closest mechanical reference, heat load, coolant, flow rate, pressure-drop target, port layout, quantity and validation requirement.
Can ToneCooling confirm compatibility from the socket name alone?
No. Socket or platform names are useful references, but final layout and performance review require the customer drawing, server envelope and validation plan.
Where are these server CPU cold plates manufactured?
Manufacturing is based in Huizhou, Guangdong, China. Public copy should not state local manufacturing for regional markets unless separately verified.
Is a complete simulation required before RFQ?
A simulation is helpful but not mandatory for first review. If simulation data is not ready, share heat load, coolant, flow rate, pressure-drop target and available envelope information.