High-Power Server CPU Cold Plate Review for 1000 W to 1500 W Classes
High-power server CPU cold plate projects in the 1000 W to 1500 W class require combined thermal, hydraulic and manufacturability review. Heat load alone is not enough; coolant condition, flow rate, pressure-drop limit, channel route, material, port layout and validation scope must be reviewed together.
Send High-Power CPU Cold Plate RequirementsView Server CPU Cold Plate Hub
Engineering Inputs to Confirm
| Heat-load class | Confirm whether the value is per processor, per plate, per module or total assembly. |
|---|---|
| Coolant and flow | Coolant type, inlet temperature, target LPM and pressure-drop budget. |
| Material/process route | Copper, aluminum, brazed, FSW or machined route must match geometry and validation needs. |
| Validation | Leak, pressure, flatness, cleanliness and sample/batch test requirement. |
High-Power Product References
These references help engineers choose the closest RFQ path before sending the official drawing, coolant condition, flow target and pressure-drop limit.

TC-1000
Current listing data for engineering confirmation: 1000 W -Pure Water -Copper
View TC-1000 product page & RFQ
TC-1200
Current listing data for engineering confirmation: 1200 W -Pure Water -Copper
View TC-1200 product page & RFQ
TC-1500
Current listing data for engineering confirmation: 1500 W -Pure Water -Copper
View TC-1500 product page & RFQRFQ Checklist
Upload a drawing, CAD file or thermal specification if available. If drawings are not ready, send the closest platform reference and the following inputs:
- Drawing or CAD file
- CPU/platform or module footprint
- Heat load and inlet temperature
- Coolant type and concentration
- Flow rate and pressure-drop target
- Port direction and hose routing
- Prototype quantity and annual demand
- Leak / pressure / cleanliness requirement
Common Review Risk
Related Server CPU Engineering Resources
Parent page for server CPU cold plates, platform RFQ paths and module review.
Drawing, heat load, coolant, pressure-drop, envelope and validation inputs for quotation review.
Prepare coolant, LPM target, inlet temperature and pressure-drop budget for high-power projects.
Review fitting direction, bend radius, hose clearance and service access before quotation.
Define leak test, pressure test, cleanliness and documentation requirements for the RFQ scope.
Check 1U, 2U or custom chassis envelope, tube route and mounting limits.
Related GPU and AI server cold plate RFQ review page.
Start a drawing-based RFQ with heat load, coolant, flow and pressure-drop inputs.
External Engineering References
FAQ
What should be sent before quotation?
Send the drawing or closest mechanical reference, heat load, coolant, flow rate, pressure-drop target, port layout, quantity and validation requirement.
Can ToneCooling confirm compatibility from the socket name alone?
No. Socket or platform names are useful references, but final layout and performance review require the customer drawing, server envelope and validation plan.
Where are these server CPU cold plates manufactured?
Manufacturing is based in Huizhou, Guangdong, China. Public copy should not state local manufacturing for regional markets unless separately verified.
Is a complete simulation required before RFQ?
A simulation is helpful but not mandatory for first review. If simulation data is not ready, share heat load, coolant, flow rate, pressure-drop target and available envelope information.