NVIDIA H200 Liquid Cooling Plate – HGX H200 Direct-to-Chip Cold Plate Kit

In the fields of high-performance computing, gaming, and content creation, NVIDIA GPUs are the preferred choice for many users due to their powerful graphics processing capabilities and exceptional performance. However, as GPU performance continues to improve, cooling issues have become increasingly prominent. The NVS H20 liquid cooling plate, with its efficient cooling performance and innovative design, is the perfect companion for NVIDIA GPUs, helping to unleash their full potential.

Products Categories
Get A Free Quote
Quote Request

Advantages of Pairing NVIDIA GPU with NVS H20 Liquid Cooling Plate:

  • Efficient Cooling, Stable Operation: The NVS H20 liquid cooling plate features an advanced liquid cooling circulation system, paired with a large pure copper base and high-density cooling fins. It rapidly dissipates heat generated by the GPU, effectively lowering GPU temperatures and ensuring system stability, preventing performance throttling or crashes caused by overheating.
  • Quiet Operation, Immersive Experience: Compared to traditional air coolers, the NVS H20 liquid cooling plate operates more quietly, significantly reducing noise interference. This allows you to fully immerse yourself in gaming or creative work without distractions.
  • Sleek Design, Showcasing Personality: The NVS H20 liquid cooling plate boasts a minimalist and stylish design, with customizable RGB lighting that can sync with other hardware in your case, creating a personalized gaming atmosphere.
  • Wide Compatibility, Easy Installation: The NVS H20 liquid cooling plate supports mainstream NVIDIA GPUs and is easy to install, making it accessible even for beginners.

T-HS202322 H20 Liquid Cooling Plate

NVIDIA GPU+NVS Cooper TLP(Transient Liquid-phase Diffusion Bonding) 700W*8+186W*4 Pure Water 45°C <80℃ 10LPM,40KPa 1MPa 409.18*331*139.61

Who is the NVIDIA GPU and NVS H20 Liquid Cooling Plate Combo For?

  • Gamers: Prolonged gaming sessions place high demands on GPU cooling. The NVS H20 liquid cooling plate effectively lowers GPU temperatures, ensuring smooth gameplay and an enhanced gaming experience.
  • Content Creators: Software like video editing and 3D rendering requires high GPU performance. The NVS H20 liquid cooling plate provides a stable cooling environment for the GPU, boosting productivity.
  • Overclocking Enthusiasts: Overclocking generates additional heat, and the NVS H20 liquid cooling plate meets the extreme cooling needs of overclockers, unlocking the full potential of the GPU.

The NVIDIA H200 liquid cooling plate from ToneCooling is a T2 purple copper direct-to-chip cold plate purpose built for the NVIDIA Hopper H200 GPU, HGX H200 8-GPU baseboards, and SXM5 modules. This H200 GPU cold plate is a precision copper heat exchanger that mounts directly on the H200 package and removes up to 700 W per GPU – a complete HGX H200 kit dissipates 8 x 700 W + 2 x 134 W + 2 x 156 W = 6180 W per baseboard into a single-phase liquid loop, replacing the air-cooled heatsinks that can no longer keep up with Hopper class AI training workloads. We manufacture this NVIDIA H200 cold plate in our ISO 9001:2015 certified facility using a continuous nitrogen-protection brazing tunnel furnace, ship prototypes at MOQ 5 pcs in 7-15 business days, and support OEM customisation of port location, manifold integration, and surface finish.

NVIDIA H200 HGX 8-GPU cold plate assembly with NVSwitch - ToneCooling AI infrastructure cooling
ToneCooling H200 GPU cold plate system – 8x GPU cold plates (700 W each) plus 4x NVSwitch cold plates with matched manifold for HGX H200 8-GPU baseboards, 6180 W total per baseboard.

What Is an NVIDIA H200 Liquid Cooling Plate?

Direct answer: A NVIDIA H200 liquid cooling plate is a T2 purple copper direct-to-chip (DTC) cold plate that bolts on top of an NVIDIA H200 GPU and removes heat by circulating liquid coolant through internal micro-channels, delivering 3 – 5x the heat transfer of an equivalent air cooler.

NVIDIA’s H200 is the memory-upgraded Hopper GPU introduced for large-language-model inference and training, shipping with 141 GB of HBM3e memory and a ~700 W thermal envelope in the SXM5 form factor. At that power density an air-cooled HGX baseboard requires > 35 CFM per GPU – impractical in 80+ kW racks. A dedicated NVIDIA H200 cold plate solves this by evacuating heat directly from the GPU package into a facility water loop running per ASHRAE TC 9.9 W45/W55 datacom guidelines. ToneCooling’s plate mates to either single-GPU SXM5 sockets or complete HGX H200 8-GPU boards, and scales from prototype evaluation kits to full production NVL deployments compatible with NVIDIA’s HGX H200 reference designs.

NVIDIA H200 HGX 8-GPU + NVSwitch liquid cooling cold plate assembly T2 purple copper nitrogen tunnel brazed
HGX H200 cold plate assembly – 8x GPU cold plates (151 x 78.2 x 43.14 mm) plus NVSwitch cold plates (80 x 64.3 x 7.6 mm), T2 purple copper nitrogen tunnel brazed, rated 0.8 MPa.

H200 Cold Plate Specifications (Datasheet)

Direct answer: ToneCooling’s H200 cold plate is a nitrogen tunnel-brazed T2 purple copper assembly rated 700 W per GPU at 38 C pure-water inlet and 8.0 L/min, with a total HGX-level heat dissipation of 6180 W per baseboard.

Parameter Value
Compatible package NVIDIA H200 SXM5, HGX H200 8-GPU baseboard, NVSwitch
Heat dissipation (per baseboard) 8 x 700 W GPU + 2 x 134 W + 2 x 156 W NVSwitch = 6180 W total
Material Purple copper T2 (oxygen-free high-conductivity, ~391 W/m.K)
Welding process Continuous Nitrogen Protection Brazing Tunnel Furnace
Working fluid Pure water (50/50 EGW, PG25 and deionised water optional per Open Compute Project cooling environment spec)
Inlet temperature 38 C (rated operating point)
Nominal flow rate 8.0 L/min per GPU cold plate
Flow resistance (pressure drop) 18.5 kPa +/- 20 % at 8.0 L/min, pure water
Working pressure 0.8 MPa (8 bar); helium leak tested
Cold plate surface temperature Below 65 C at rated conditions
GPU cold plate dimensions 151 x 78.2 x 43.14 mm (L x W x H)
NVSwitch cold plate dimensions 80 x 64.3 x 7.6 mm (L x W x H)
Ports G1/4 BSPP standard; custom manifold + dripless quick disconnects optional
Standards ISO 9001:2015 manufactured, RoHS compliant
MOQ and lead time 5 pcs prototype in 7 – 15 business days; 50 pcs production in 4 – 6 weeks
H200 cold plate CFD thermal simulation 38C pure water inlet surface temperature below 65C
ToneCooling CFD thermal simulation of the H200 cold plate loop – 38 C pure-water inlet at 8.0 L/min per GPU, cold plate surface temperature held below 65 C across the full HGX baseboard.

How Does the H200 Cold Plate Improve GPU Performance?

Direct answer: By holding the H200 cold plate surface below 65 C at a 38 C pure-water inlet and 8.0 L/min, the liquid cooling plate keeps the GPU junction out of thermal throttling, recovering 8 – 12 % of sustained training throughput relative to an air-cooled SXM5 platform.

In a ToneCooling internal validation run we measured a complete HGX H200 baseboard using the cold plate shown above at a 38 C facility-water inlet and 8.0 L/min per GPU (pure water). CFD simulation and bench measurement both confirmed the cold plate surface held below 65 C while the full baseboard dissipated the rated 6180 W (8 x 700 W GPU + 2 x 134 W + 2 x 156 W NVSwitch). That is well below the ~90 C throttle point of the Hopper architecture, which directly maps to longer GPU boost clock residency and measurable gains in tokens-per-second on Llama-3 70B inference workloads. Because the H200 cold plate assembly also removes heat from every NVSwitch on the baseboard, the whole HGX unit stays inside the ASHRAE W45 envelope even at 80 kW rack power.

H200 HGX Rack Integration and OEM Customisation

Direct answer: ToneCooling supplies matched cold plates, manifolds, and dripless quick disconnects for HGX H200 baseboards, and co-engineers the complete rack loop with hyperscale OEMs via CFD before tooling.

Every HGX H200 cold plate kit we ship includes CFD-validated flow distribution across all 8 GPUs and both NVSwitch pairs, a bench-tested flow-resistance curve at 8.0 L/min, and PPAP documentation for OEM qualification. We support three common rack architectures: (1) rear-door heat exchanger retrofit, (2) in-row CDU loops, and (3) direct facility-water plumbing to an external dry cooler. Customisation options include port position, manifold geometry, electroless nickel plating for mixed-metal loops, and integrated temperature/flow instrumentation. The GPU cold plate measures 151 x 78.2 x 43.14 mm and each NVSwitch cold plate measures 80 x 64.3 x 7.6 mm, allowing retrofit into standard HGX chassis envelopes without mechanical interference.

H200 GPU cold plate flow resistance curve 18.5 kPa at 8 LPM pure water
Measured flow-resistance curve for the ToneCooling H200 GPU liquid cooling plate – 18.5 kPa +/- 20 % at the 8.0 L/min pure-water nominal operating point, sized to match standard CDU secondary loops.

Frequently Asked Questions About the H200 Cold Plate

Is this H200 cold plate compatible with the HGX H200 8-GPU baseboard?

Yes. The NVIDIA H200 liquid cooling plate is engineered for both single SXM5 sockets and complete HGX H200 8-GPU baseboards, and it is supplied with matched NVSwitch cold plates (80 x 64.3 x 7.6 mm) for full-baseboard direct-to-chip cooling. Total rated heat dissipation is 6180 W per HGX baseboard.

What flow rate and pressure drop should I design the CDU loop for?

Design the secondary loop for 8.0 L/min per GPU cold plate with pure water. At that operating point our H200 cold plate has a measured flow resistance of 18.5 kPa +/- 20 %. The cold plate is rated for 0.8 MPa (8 bar) working pressure and helium leak tested before shipping.

What thermal performance can I expect on a 700 W H200 SXM5?

At the rated 38 C pure-water inlet and 8.0 L/min per GPU, the ToneCooling H200 cold plate holds its surface temperature below 65 C while dissipating the full 700 W per GPU (and 134 – 156 W per NVSwitch), well below the 90 C throttle point and sufficient for full H200 boost clock residency under Llama-3 class inference loads.

What material and brazing process do you use for the H200 cold plate?

Every ToneCooling H200 cold plate is built from T2 purple copper (oxygen-free high-conductivity grade, ~391 W/m.K) and joined in a continuous nitrogen protection brazing tunnel furnace. Nitrogen atmosphere tunnel brazing eliminates oxide formation at the fin-to-base interface, producing a metallurgically bonded joint with lower thermal resistance and higher thermal cycling durability than epoxy-bonded or solder-bonded plates.

Do you support OEM PPAP qualification for HGX H200 cold plates?

Yes. ToneCooling ships PPAP Level 3 documentation including material certificates for the T2 copper, helium leak test records, hydrostatic burst test data, and CFD validation reports, aligned with hyperscale and automotive OEM qualification processes. Prototype MOQ is 5 pcs with a 7 – 15 business day lead time.

Lead Time, MOQ, and Pricing for the H200 Cold Plate

  • Prototype: MOQ 5 pcs, 7 – 15 business days from confirmed drawing
  • Production: MOQ 50 pcs, 4 – 6 weeks depending on volume
  • Indicative pricing: USD 700 – 1800 per unit at production volume; prototype quote within one business day
  • Documentation: Free CFD review, flow-resistance curve, and T2 copper material certificates included
  • Shipping: Worldwide air freight from Shenzhen, full export documentation for US and EU customs

For complementary platforms, see our liquid cold plate catalogue, our NVIDIA GB200 liquid cooling plate, and our dedicated CPU cold plate range. If you need a quote for the NVIDIA H200 liquid cooling plate or a custom HGX H200 manifold kit, request a quote and our thermal engineering team will respond within one business day.

Author: ToneCooling Engineering Team (Thermal Engineer). Last Updated: 2026-04-10.

Need a Custom Cold Plate for Your Project?

Send us your STEP/PDF file with TDP, coolant type, and flow requirements. Our engineers will deliver a thermal design proposal within 24 hours.

✓ ISO 9001 Certified  |  ✓ MOQ 5 pcs  |  ✓ Prototype in 4–6 weeks  |  ✓ NDA Available

Need a Custom Liquid Cold Plate?

Tell us your thermal requirements. Engineering team responds within 48 hours with design proposal and quotation.

Request a Quote →

MOQ 5 pcs • Prototype 7-15 days • ISO 9001 Certified

Related Products

Related News

What Is Additive Manufacturing Achieves Lightweight Cold? Additive Manufacturing Achieves Lightweight Cold is a high-performance thermal management solution engineered by […]

This comprehensive guide covers things to know before solutions for industrial and OEM applications. ToneCooling provides expert insights on things […]

Efficient thermal management is crucial for electric vehicle (EV) batteries and power electronics. Cold plates play a key role in […]

This comprehensive guide covers how additive manufacturing improves solutions for industrial and OEM applications. ToneCooling provides expert insights on how […]

What Is Transient Liquid Phase Tlp Bonding? Definition and basic process — Transient liquid phase TLP bonding is a joining […]

Bionic Blood Vessel Structure High is a high-performance thermal management solution engineered by ToneCooling for demanding applications. A bionic blood […]

Water cooling provides superior heat dissipation for processors. This method allows higher clock speeds and greater system stability. Users achieve […]

CPU cooling plays a critical role in system performance and stability. Builders today can choose from several methods, including air […]

Scroll to Top

Get A Free Quote Now !

If you have any questions, please do not hesitate to contact us.

Quote Request
ToneCooling 19 thermal management
Get a Quote — 48h Response