Guangdong, China
Global Engineering RFQ Review
ToneCooling H20 liquid cold plate
ToneCooling H20 liquid cold plate

NVIDIA H200 Liquid Cooling Plate: HGX H200 Direct-to-Chip Kit

In the fields of high-performance computing, gaming, and content creation, NVIDIA GPUs are the preferred choice for many users due to their powerful graphics processing capabilities and exceptional performance. However, as GPU performance continues to improve, cooling issues have become increasingly prominent. The NVS H20 liquid cooling plate, with its efficient cooling performance and innovative design, is the perfect companion for NVIDIA GPUs, helping to unleash their full potential.

Products Categories
Get A Free Quote
Quote Request

Advantages of Pairing NVIDIA GPU with NVS H20 Liquid Cooling Plate:

  • Efficient Cooling, Stable Operation: The NVS H20 liquid cooling plate features an advanced liquid cooling circulation system, paired with a large pure copper base and high-density cooling fins. It rapidly dissipates heat generated by the GPU, effectively lowering GPU temperatures and ensuring system stability, preventing performance throttling or crashes caused by overheating.
  • Quiet Operation, Immersive Experience: Compared to traditional air coolers, the NVS H20 liquid cooling plate operates more quietly, significantly reducing noise interference. This allows you to fully immerse yourself in gaming or creative work without distractions.
  • Sleek Design, Showcasing Personality: The NVS H20 liquid cooling plate boasts a minimalist and stylish design, with customizable RGB lighting that can sync with other hardware in your case, creating a personalized gaming atmosphere.
  • Wide Compatibility, Easy Installation: The NVS H20 liquid cooling plate supports mainstream NVIDIA GPUs and is easy to install, making it accessible even for beginners.

T-HS202322 H20 Liquid Cooling Plate

NVIDIA GPU+NVSCooperTLP(Transient Liquid-phase Diffusion Bonding)700W*8+186W*4Pure Water45°C<80℃10LPM,40KPa1MPa409.18*331*139.61

Who is the NVIDIA GPU and NVS H20 Liquid Cooling Plate Combo For?

  • Gamers: Prolonged gaming sessions place high demands on GPU cooling. The NVS H20 liquid cooling plate effectively lowers GPU temperatures, ensuring smooth gameplay and an enhanced gaming experience.
  • Content Creators: Software like video editing and 3D rendering requires high GPU performance. The NVS H20 liquid cooling plate provides a stable cooling environment for the GPU, boosting productivity.
  • Overclocking Enthusiasts: Overclocking generates additional heat, and the NVS H20 liquid cooling plate meets the extreme cooling needs of overclockers, unlocking the full potential of the GPU.

H200 liquid cooling from ToneCooling is a standard T2 copper cold plate set, part number TC-BZP-H200-01A, for H200 (SXM5) 8-GPU + NVSwitch boards. It handles 8 × 700 W GPU plus 2 × 134 W + 2 × 156 W NVSwitch loads at a 38 °C pure-water inlet and 8.0 L/min, keeping the plate surface below 65 °C.

ToneCooling H200 cold plate set with eight GPU cold plates, NVSwitch cold plates, two manifolds and color-coded quick disconnects
ToneCooling H200 GPU + NVSwitch liquid cold plate set, part number TC-BZP-H200-01A.

Request an H200 quote Download H200 datasheet (PDF)

H200 Cold Plate Specifications (TC-BZP-H200-01A, Rev B)

The H200 cold plate set is rated for 8 × 700 W + 2 × 134 W + 2 × 156 W, which is 6,180 W per 8-GPU board (calculated), at 38 °C inlet and 8.0 L/min of pure water. Flow resistance is 18.5 kPa (±20%) and maximum operating pressure is 0.8 MPa.

ParameterValue
Part numberTC-BZP-H200-01A (standard product)
PlatformH200 (SXM5) 8-GPU + NVSwitch boards
Heat dissipation (W)8 × 700 W GPU + 2 × 134 W + 2 × 156 W NVSwitch
CoolantPure water
Feed liquid (°C, L/min)38 °C inlet, 8.0 L/min
Flow resistance (kPa)18.5 kPa (±20%)
Max operating pressure (MPa)0.8 MPa
Cold-plate surface temperature (°C)< 65 °C at the reference operating point
Thermal resistanceCFD-validated per project
MaterialT2 copper
JoiningContinuous nitrogen-protection brazing (tunnel furnace)
GPU plate dimensions (mm)151 × 78.2 × 43.14 mm
NVSwitch plate dimensions (mm)80 × 64.3 × 7.6 mm
ConnectorQuick disconnect, specified per project
Leak test100% tested: helium ≤ 1 × 10−9 mbar·L/s or pressure test, criteria per project

Source: ToneCooling datasheet TC-BZP-H200-01A, Rev B (2026-10). Stated figures are the reference operating point for this standard set; final values are confirmed against your platform and system-level boundary conditions.

Request an H200 quote Datasheet PDF, no form required

What Is Included in the H200 Liquid Cooling Set?

The set covers every hot device on an H200 8-GPU board: eight GPU cold plates and NVSwitch cold plates for the four NVSwitch heat loads (2 × 134 W + 2 × 156 W). Connectors are quick disconnects chosen per project, so the set can plug into your existing manifold or a manifold we build to your drawing.

H200 GPU and NVSwitch copper cold plates by ToneCooling
GPU plates are 151 × 78.2 × 43.14 mm; NVSwitch plates are 80 × 64.3 × 7.6 mm.

How Should You Size the Coolant Loop for H200 Liquid Cooling?

Start from the datasheet reference point: 38 °C pure-water inlet, 8.0 L/min feed flow and 18.5 kPa (±20%) flow resistance, with the loop rated to 0.8 MPa. Your CDU or facility loop must deliver that flow at that pressure drop for every board on the rack, plus the losses of manifolds, hoses and quick disconnects.

  • Heat to remove per board: 6,180 W (calculated from 8 × 700 W + 2 × 134 W + 2 × 156 W).
  • Inlet temperature: the 38 °C rating suits warm-water loops; other inlet temperatures and coolants are evaluated by CFD for your project.
  • CDU: ToneCooling also supplies the coolant distribution unit (CDU), so cold plates and CDU can be quoted as one package or matched to the CDU you already use.

Testing, Quality and Documentation

  • Made in our own manufacturing facility in Huizhou, China, under an IATF 16949-aligned quality system.
  • 100% leak testing: helium ≤ 1 × 10−9 mbar·L/s or pressure test, with acceptance criteria per project.
  • Proof and burst pressure tested per project requirement; thermal cycling per IEC 60068-2-14; ultrasonic C-scan of bonded joints per ASTM E2375.
  • Thermal resistance, leak and flatness test reports are available on request; RoHS / REACH documentation on request.

What Should You Send With an H200 Cold Plate RFQ?

Send the board type (H200 SXM5 8-GPU + NVSwitch), quantity, coolant, inlet temperature, available flow per board, allowed pressure drop, connector type and any manifold or chassis drawing. Custom samples are available from a single piece. An engineer reviews every RFQ and replies by email with next steps. For a full input list, see the H200 cold plate RFQ checklist.

Need the STEP model or test report first? Use the form below.

STEP Model & Test Report Request

Frequently Asked Questions About H200 Liquid Cooling

Is the TC-BZP-H200-01A set compatible with HGX H200 8-GPU boards?

It is designed for H200 (SXM5) 8-GPU + NVSwitch boards and covers both the GPU and NVSwitch positions. Send your board and tray drawing with the RFQ and an engineer confirms mechanical fit and port positions before you order.

What flow rate and pressure drop should I design the CDU loop for?

Design for the datasheet reference point: 8.0 L/min of pure water at a 38 °C inlet, with 18.5 kPa (±20%) flow resistance and a 0.8 MPa maximum operating pressure. Add the pressure losses of your manifolds, hoses and quick disconnects.

How big is the H200 cold plate?

Each GPU cold plate measures 151 × 78.2 × 43.14 mm and each NVSwitch cold plate measures 80 × 64.3 × 7.6 mm. Both are T2 copper, joined by continuous nitrogen-protection brazing.

How much does H200 liquid cooling cost?

The H200 cold plate set is quoted per project, because quantity, connectors, manifold scope and test documentation change the cost. Send an RFQ with your requirements and an engineer replies by email with a quotation.

Can I order a single H200 sample, and what is the lead time?

Yes. Custom samples are available from a single piece and are typically ready in 4–6 weeks, including design review. Production lead time is normally 6–8 weeks and is confirmed in the quotation.

Is every H200 cold plate leak tested, and can I get test reports?

Yes. Every set is 100% leak tested with helium (≤ 1 × 10−9 mbar·L/s) or a pressure test, with criteria per project. Thermal resistance, leak and flatness reports are available on request, and the H200 datasheet downloads without a form.

Other Standard GPU Cold Plate Kits

Compare the H200 set with our GB300 4G+2C cold plate kit, the GB200 cold plate kit and the H100 8-GPU cold plate assembly, or browse all liquid cold plates, including custom designs.

Last updated: 2026-10-19 · ToneCooling Engineering Team. NVIDIA and H200 are trademarks of NVIDIA Corporation; no affiliation or endorsement is implied.

Related guides

Related products

Related Products

Related News

Additive manufacturing builds cold plates layer by layer, allowing lightweight, complex internal channels that machining cannot make, at higher cost […]

Before buying liquid cold plates in bulk, confirm the specification, approve samples, agree on test methods and records, and check […]

Straight-channel cold plates have low pressure drop but can leave a temperature gradient along the flow, while inclined channels mix […]

What Is Transient Liquid Phase Tlp Bonding? Definition and basic process — Transient liquid phase TLP bonding is a joining […]

A bionic blood-vessel cold plate uses branching channels modeled on natural vascular networks to spread coolant evenly and cut pressure […]

Water cooling improves processor performance by carrying heat away from the CPU faster than air, so the chip stays below […]

A cold plate cools a CPU better than air coolers and most AIOs when it is part of a well-designed […]

Scroll to Top

Get A Free Quote Now !

If you have any questions, please do not hesitate to contact us.

Quote Request
ToneCooling 19 thermal management