Guangdong, China
Global Engineering RFQ Review

Data Center Cold Plate RFQ Inputs for GPU Cooling Projects

Table of Contents
ToneCooling GB200 cold plate kit on a mounting plate with braided hoses and quick disconnect fittings
Engineering image for this RFQ topicThis image shows the closest cold plate family for the topic. Final RFQ review still requires drawing, heat load, coolant, flow rate and pressure-drop target.

A data center GPU cold plate RFQ should start with engineering inputs, not a generic product description. The drawing, heat source map, coolant condition and hydraulic target determine whether a cold plate can be reviewed for manufacturability and quotation.

For the main RFQ path, review data center liquid cold plate RFQ review and prepare the engineering inputs before requesting quotation.

ToneCooling GB300 4G+2C liquid cold plate kit with four GPU cold plates, two CPU cold plates, manifold, hoses and red and blue quick disconnects

Related product path

Open this product path when the project platform or cold plate family matches your RFQ.

H200 GPU liquid cold plate for data center cooling

Engineering review input

Use this path for drawing, port layout, pressure-drop or validation review.

ToneCooling GB200 cold plate kit on a mounting plate with braided hoses and quick disconnect fittings

Main data center RFQ page

Return to the main data center liquid cold plate page for the complete RFQ checklist.

Start with the mechanical package

  • 2D drawing, STEP file or module envelope
  • GPU, accelerator or CPU footprint
  • Stack height, mounting space and port direction
  • Connector or hose clearance limits

Define the thermal and hydraulic targets

  • Heat load by source area
  • Coolant type and inlet temperature
  • Target flow rate in LPM
  • Pressure-drop target or maximum limit

State validation requirements

  • Leak test requirement
  • Pressure test requirement
  • Flatness or contact surface requirement
  • Cleanliness and documentation requirement

RFQ checklist

  • Drawing, CAD file or thermal specification
  • Heat load and heat source map
  • Coolant type and inlet temperature
  • Flow rate and pressure-drop target
  • Envelope, port orientation and mounting limits
  • Leak, pressure, cleanliness and documentation requirements

Official Platform References

Use these OEM platform pages as reference context only. ToneCooling RFQ review still requires the customer-approved drawing, module envelope, heat load, coolant, flow rate and pressure-drop target.

FAQ

Can ToneCooling quote without a final drawing?

A final quotation needs enough engineering data for review. If the drawing is not ready, send the closest available footprint, heat load, coolant, flow rate, pressure-drop target and envelope information.

Should platform names such as GB200 or GB300 be used in the RFQ?

Yes, when they identify the project platform. The official platform drawing and customer-approved requirements are still needed before quotation.

Where are ToneCooling data center cold plates manufactured?

Manufacturing is based in Huizhou, Guangdong, China. Regional websites should describe local communication or project coordination only when applicable.

Request data center liquid cold plate RFQ review

Related articles

Picture of ToneCooling Engineering Team
ToneCooling Engineering Team

The ToneCooling thermal engineering team designs, simulates, and validates custom liquid cold plates for GPU, CPU, IGBT, and EV battery applications.

Welcome To Share This Page:
Product Categories
Latest News
Get A Free Quote Now !
Quote Request

Related Products

Related News

ToneCooling publishes measured datasheets and factory test results for its standard GB300 4G+2C (TC-BZP-GB300-01A) and GB200 (TC-BZP-GB200-01A) direct-to-chip cold plate kits.
Drawing preparation checklist for data center liquid cold plate quotation, covering CAD files, heat source maps, port layout, material and validation inputs.
Validation items engineers should define before requesting a data center liquid cold plate quote, including leak test, pressure test, cleanliness and documentation.
Copper and aluminum cold plate tradeoffs for AI server projects, including thermal performance, weight, corrosion, joining route and RFQ inputs.
Engineering checklist for direct-to-chip cold plate port layout, hose clearance, serviceability and RFQ preparation in AI server cooling projects.
How to prepare pressure-drop and flow-rate inputs for custom GPU liquid cold plate RFQs used in AI server and data center cooling projects.
RFQ inputs engineers should prepare for data center GPU cold plates, including drawings, heat load, coolant, flow rate, pressure-drop target and validation requirements.

ToneCooling (ToneCooling Technology Co., Ltd) has completed its new 30,000m² manufacturing facility in Huizhou, Guangdong, China — an RMB 80

Scroll to Top

Get A Free Quote Now !

If you have any questions, please do not hesitate to contact us.

Quote Request
ToneCooling 19 thermal management