Guangdong, China
Global Engineering RFQ Review
ToneCooling T-HS202332 tec liquid cold plate for battery swap semiconductor test, product view
ToneCooling T-HS202332 tec liquid cold plate for battery swap semiconductor test, product view

TEC Liquid Cold Plate for Battery Swap & IC Test | T-HS202332

Small-format 95 × 64 × 14 mm aluminium cold plate for rejecting heat from the hot side of two 65 W thermoelectric modules. Friction-stir-welded, 0.2 MPa rating for low-pressure closed loops. Pure water at 3.5 LPM / 7.5 kPa and 25 °C inlet holds the TEC hot side at 29 °C (4 K rise) — the tight hot-side temperature that lets the TEC reach its rated ΔT for precision control.

  • 65 W × 2 at < 29 °C surface with 25 °C inlet — 4 K case-to-inlet rise on pure water
  • 7.5 kPa at 3.5 LPM — moderate pressure drop, sized for standard CDU branches
  • 95 × 64 × 14 mm — 14 mm profile; port position to your chassis layout
  • FSW aluminium, 0.2 MPa rated — every unit leak-tested before shipment
Products Categories
Get A Free Quote
Quote Request

Engineering overview

  • Thermal: 4 K case-to-inlet rise at rated load, measured at the contact area with pure water. Thermal interface material and mounting pressure set the final junction temperature — we supply the recommended TIM and torque spec with each order.
  • Hydraulic: 7.5 kPa at 3.5 LPM — moderate pressure drop, sized for standard CDU branches; validated on our flow bench at the rated inlet temperature of 25 °C.
  • Mechanical: 95 × 64 × 14 mm aluminium plate, 14 mm overall height. Mounting pattern matches the target device; custom port orientation and fittings on request.
  • Construction: FSW – Friction Stir Welding — a homogeneous metallurgical joint with no braze filler or flux residue in the coolant path; 0.2 MPa working pressure, 100% pressure-tested.
  • Fittings: G1/4 quick-disconnect, barb or custom per drawing; inlet/outlet position to your chassis layout.

T-HS202332 Specifications (as tested)

ParameterValue
ModelT-HS202332
Target deviceTEC for Battery Swap & Semiconductor Test
Rated heat load65 W × 2
Coolant (as tested)Pure water
Inlet coolant temperature25 °C
Max. plate surface temperature< 29 °C
Case-to-inlet thermal resistance≈ 0.062 °C/W per device (from rated point)
Flow rate / pressure drop3.5 LPM / 7.5 kPa
Working pressure rating0.2 MPa
Dimensions (L × W × H)95 × 64 × 14 mm
Base materialAluminium
Bonding processFSW – Friction Stir Welding
Leak test100% pressure-tested before shipment

Typical applications

  • EV battery swapping stations
  • Semiconductor test and burn-in equipment
  • Precision temperature-control modules

Ordering & RFQ

How to order: quote model T-HS202332 with quantity and required fitting type. Samples 1–5 pcs with leak-test report; production quantities after drawing approval.

RFQ checklist: target device and heat load, quantity, coolant type, inlet temperature, target flow rate and available envelope. Send a STEP/PDF of your tray or assembly if port position matters.

FAQ

Can it run on warm water? The rated point is 25 °C inlet with pure water. Other inlet temperatures and coolants (pure water, EGW, PGW) are supported — performance is validated per coolant on request.

Can the ports or fittings be customised? Yes — fitting type, thread and inlet/outlet position are set per drawing without changing the qualified core.

What is included? Cold plate, mounting hardware, recommended TIM and torque spec, leak-test report. Datasheet PDF available above; STEP file on request.

Related Products

Related News

Battery cold plates keep EV and energy storage cells inside their safe temperature window by conducting heat into a liquid […]

EV batteries are cooled by air, by liquid cold plates or by direct refrigerant; liquid cold plates are the most […]

What Is Transient Liquid Phase Tlp Bonding? Definition and basic process — Transient liquid phase TLP bonding is a joining […]

EV battery cooling works by pumping a coolant through cold plates under or between the cells, so heat from charging […]

Water cooling improves processor performance by carrying heat away from the CPU faster than air, so the chip stays below […]

A cold plate cools a CPU better than air coolers and most AIOs when it is part of a well-designed […]

You need liquid cooling when your processor or GPU cannot stay below its temperature limit with air at acceptable noise […]

The best liquid cold plate brand for an OEM project is the supplier that can show measured data for your […]

Scroll to Top

Get A Free Quote Now !

If you have any questions, please do not hesitate to contact us.

Quote Request
ToneCooling 19 thermal management