Multi-emitter aluminium cold plate assembly for laser projection light engines, cooling six 200 W laser sources (1.2 kW) on one manifold, 482 × 200 × 255 mm. Friction-stir-welded, 0.5 MPa. 25% PGW at 3 LPM / 20 kPa and 40 °C inlet keeps emitter surfaces below 55 °C, holding wavelength and output stable over long duty cycles.

  • 200 W × 6 at < 55 °C surface with 40 °C inlet — 15 K case-to-inlet rise on 25% PG / water (PGW)
  • 20 kPa at 3 LPM — sized for a dedicated CDU branch at the rated flow
  • 482 × 200 × 255 mm — 255 mm profile; port position to your chassis layout
  • FSW aluminium, 0.5 MPa rated — every unit leak-tested before shipment
Products Categories
Get A Free Quote
Quote Request

Engineering overview

  • Thermal: 15 K case-to-inlet rise at rated load, measured at the contact area with 25% PG / water (PGW). Thermal interface material and mounting pressure set the final junction temperature — we supply the recommended TIM and torque spec with each order.
  • Hydraulic: 20 kPa at 3 LPM — sized for a dedicated CDU branch at the rated flow; validated on our flow bench at the rated inlet temperature of 40 °C.
  • Mechanical: 482 × 200 × 255 mm aluminium plate, 255 mm overall height. Mounting pattern matches the target device; custom port orientation and fittings on request.
  • Construction: FSW – Friction Stir Welding — a homogeneous metallurgical joint with no braze filler or flux residue in the coolant path; 0.5 MPa working pressure, 100% pressure-tested.
  • Fittings: G1/4 quick-disconnect, barb or custom per drawing; inlet/outlet position to your chassis layout.

T-HS202333 Specifications (as tested)

ParameterValue
ModelT-HS202333
Target deviceLaser Projection — 6-Emitter
Rated heat load200 W × 6
Coolant (as tested)25% PG / water (PGW)
Inlet coolant temperature40 °C
Max. plate surface temperature< 55 °C
Case-to-inlet thermal resistance≈ 0.075 °C/W per device (from rated point)
Flow rate / pressure drop3 LPM / 20 kPa
Working pressure rating0.5 MPa
Dimensions (L × W × H)482 × 200 × 255 mm
Base materialAluminium
Bonding processFSW – Friction Stir Welding
Leak test100% pressure-tested before shipment

Typical applications

  • Laser cinema and large-venue projectors
  • Laser TV and simulation displays
  • Industrial laser light engines

Ordering & RFQ

How to order: quote model T-HS202333 with quantity and required fitting type. Samples 1–5 pcs with leak-test report; production quantities after drawing approval.

RFQ checklist: target device and heat load, quantity, coolant type, inlet temperature, target flow rate and available envelope. Send a STEP/PDF of your tray or assembly if port position matters.

FAQ

Can it run on warm water? The rated point is 40 °C inlet with 25% PG / water (PGW). Other inlet temperatures and coolants (pure water, EGW, PGW) are supported — performance is validated per coolant on request.

Can the ports or fittings be customised? Yes — fitting type, thread and inlet/outlet position are set per drawing without changing the qualified core.

What is included? Cold plate, mounting hardware, recommended TIM and torque spec, leak-test report. Datasheet PDF available above; STEP file on request.

Related Products

Related News

Nvidia Al GPU Liquid Cooling Server 3000W GPU liquid cooling cold plates for AI servers are becoming essential as AI […]

What Is Transient Liquid Phase Tlp Bonding? Definition and basic process — Transient liquid phase TLP bonding is a joining […]

Water cooling improves processor performance by carrying heat away from the CPU faster than air, so the chip stays below […]

A cold plate cools a CPU better than air coolers and most AIOs when it is part of a well-designed […]

You need liquid cooling when your processor or GPU cannot stay below its temperature limit with air at acceptable noise […]

The best liquid cold plate brand for an OEM project is the supplier that can show measured data for your […]

The main liquid cold plate types are tubed, machined, brazed fin, friction stir welded and micro-channel plates; they differ in […]

Microchannels raise liquid cold plate efficiency by increasing the wetted surface area close to the heat source, which lowers thermal […]

Scroll to Top

Get A Free Quote Now !

If you have any questions, please do not hesitate to contact us.

Quote Request
ToneCooling 19 thermal management